Versa Products Company, Inc., 22 Spring Valley Road, Paramus, New Jersey 07601 ● TEL: 201/843-2400 Fax: 201/843-2931
Versa BV., Prins Willem Alexanderlaan 1429, 7312 GB Apeldoorn, The Netherlands ● TEL: +01131-55-3681900 FAX: +01131-55-3681909
Control Valves and Components for
Process, Wellhead and Safety Shutdown Systems
BULLETIN
B316 2012
ISO 9001
CERTIFIED
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - B316 2012

®www.versa-valves.come-mail: [email protected] Products Company, Inc., 22 Spring Valley Road, Paramus, New Jersey 07601 ● TEL: 201/843-2400

Strona 2 - ACCESSIBILITY

10Single Solenoid Valves EXPilotControlled (inlet) Pressurepsi bar psi bar psi bar psi bar psi bar psi bar psi bar psi bar psi bar p

Strona 3 - CONTENTS GUIDE

11Solenoid-pilot operatedSolenoid-Pilot return(detented)Controlled (Inlet) PressureEXPilot INPilotpsi bar psi bar0-200 0-14 15-175 1-12Auxiliary pilot

Strona 4

12PRESSURESControlled (inlet) pressure & auxiliary pilot pressure (when required) are the same as those shown for the corresponding solenoid valve

Strona 5 - Manually Operates Valves

13PRESSURESControlled (inlet) pressure & auxiliary pilot pressure (when required) are the same as those shown for the corresponding solenoid valve

Strona 6 - Pilot Operated Valves

14PRESSURESControlled (inlet) pressure & auxiliary pilot pressure (when required) are the same as those shown for the corresponding solenoid valve

Strona 7 - Mechanically Operated Valves

15OPERATING PRESSUREAND WEIGHTWeightSYSTEM PRESSUREALLOWABLE BACKPRESSUREat Outlet Port (Two-Way)or Exhaust Port (Three-Way)Two-Way (2/2)Block & B

Strona 8

16MAIN SUPPLY RESET VALVES SELECTORKnob Actuator Pilot ActuatorValve SufxNon-latching Manual Pin Latch Non-indicating Indicating Air Pilot Air Latch

Strona 9

17INEXCYLINDICATOR DEVICE REFFERENCE • RED INDICATES THAT THERE IS NO PRESSURE IN THE PILOT CHAMBER • GREEN INDICATES THAT THE PILOT CHAMBER I

Strona 10 - SERIES B316 VALVES

18INEXCYLREDGREENINEXCYLREDGREENINEXCYLINEXCYL⅛” NPT INLINEPILOT LATCHPORTMANUALLATCHPIN⅛” NPT INLINEPILOT LATCHPORT ● GREEN INDICATES THAT THE PILOT

Strona 11 - Controlled (Inlet) Pressure

19REDGREENINEXCYLMANUAL OVERRIDE BUTTONOPTIONAL (SUFFIX -ME).4711.82.0953.224” (610mm) LEADS⅛” NPT PILOT PORT(EX-PILOT VALVES ONLY)MANUAL LATCH PIN3.4

Strona 12

2THE COMMITMENT CONTINUES Fluid Power is our business. It is our only business, so we have to be good at it. Since its beginning in 1949, Versa has

Strona 13 - (d) FLAMEPROOF

20BAA-3308-900R BAA-3308-550RConstruction:Body. Internals, Caps316 stainless steel (NACE MR-01-75)Hardcoated Aluminum (MIL-A-8625E, Type III, Class1)S

Strona 14

21BAA-3308-900RA BAA-3308-550RA316 Stainless Steel (NACE MR-01-75)Construction: Body, Internals, CapsHardcoated Aluminum (MIL-A-8625E, Type III, Clas

Strona 15 - Porting Size and Flow

22BAA-3308-550RABConstruction: Body, Internals, CapsHardcoated Aluminum (MIL-A-8625E, Type III, Class 1) Seals FKM (uorocarbon) Fasteners & By

Strona 16 - STAINLESS STEEL CONSTRUCTION

23ValveProduct NumberRepairKit NumberALL*B-3308-316Manual- BSI or BIACam- BSCPilot- BSP or BPP *Additional nonhazardous solenoid parts not included in

Strona 17 - Knob: Latching, Indicating

The warnings below must be read and reviewed before designing a system utilizing, installing, servicing, or removing a Versa product. Improper use, in

Strona 18 - INDICATOR DEVICE REFERENCE

3Versa exercises diligence to assure that information contained in this catalog is correct, but does not accept re-sponsibility for any errors or omis

Strona 19 - Type: Specialized Application

4TYPE OF SERVICETemperature Range (Medium/Ambient Temperature)Intermittent Duty Service Continuous Duty ServiceAC or DC AC DCCoil Solenoid Plunger* Co

Strona 20 - Transmitting Relay Circuit

5Ø1.81461.025.4Ø MIN PANEL HOLE4.64117.9.15 3.8TRAVEL6.42163Ø1.025.4MIN PANEL HOLEMAX PANEL THICKNESS.5012.2.317.9WITH SUFFIX OPTION -43Ø1.81460.164.

Strona 21 - Receiving Relay Circuit

6Pilot OperatedSpring ReturnControlled (inlet) Pressurepsi bar psi bar psi bar psi bar psi bar psi bar psi bar psi bar psi bar psi

Strona 22 - Consult factory for actual

7min stroke0.133.5max stroke0.154.11.2531.7sq.0.184.6¼” NPT3 PORTS1.6642.13.3184.0.348.6.5012.71.025.41.025.4.133.3Ø.276.9AIN EXAIN EX3/2-(Three-Way)

Strona 23 - Series B316 B550 B900 VALVES

8Sufx IdenticationProtection ClassicationArea Classication and (Gas Grouping)Certication- (Conformance)Ingress ProtectionNone or-UGeneral Purpose